Monday, July 27, 2009

A Switch to Ellipsometry

Since I am running a bit short on time, we decided to move this setup today (Wednesday) from the spectroscopy setup to the ellipsometer setup to try and characterize the beam. Since the beam was probably too wide at the waist (in between the two parabolic mirrors), we placed the Si wafer in front of the receiver to look at the distribution at this position. A sketch of this is shown below (a very rough sketch... just to show placement of components).

The dotted black line again represents the excitation beam, the pink components represent the lens and lens arm, which are attached to the translational stage, shown as the grey square. The darker grey squares are the emitter and receiver for the THz signal, the blue ovals are the parabolic mirrors, and the black disc represents a mirror which the excitation beam reflects off. Finally, the grey disc again represents the Si wafer.

After taking an x- and y-lateral scan over the Si wafer, I found some very interesting looking profiles, especially in the x-direction. A plot showing both directional scans is shown below.

Clearly the x-direction is very strange, while the y-direction almost looks like an upside-down parabola. The features in the x-directional scan, I think, help to reinforce the idea that perhaps the incident angle does not have much effect on the profile of the beam and that possibly the alignment of the actual microscope is what should be adjusted in order to correct any sort of skewness. In terms of the y-direction, it would be nice to take a wider range of data; and by this, I simply mean having more data points on the edges of the scan. I hope to do this tomorrow after adjusting the lens and stage.

Overall, it is very interesting to see such an odd profile in the x-direction -- and I think the most interesting thing is that the scan is extremely smooth, as opposed to some more "rigid" scans.

I also should mention that the lock-in was much less noisy in this setup than in the spectroscopy setup. Perhaps this has to do with the THz setup in general, the excitation beam, or something else. Also note that the relative amplitude is much less than what we saw in the spectroscopy setup, where we would see amplitudes of 4 or 5 mV, here we see just over 2 mV.

Comparison of x- and y-scans With Symmetrical Setup

After aligning the excitation beam, I was able to take some scans in the x- and y-directions with the new angle of incidence of the excitation beam today (Tuesday). As I mentioned already, this "new angle" was completely opposite of the initial incident angle. To better see this, I have attached a sketch below in which the initial incidence is shown by the red setup and the switched incidence is shown by the green setup. The stand was moved a little between the two setups, but only to gain extra length on the arm which went to the lens for focusing the excitation beam.


The black dotted line represents the incident excitation beam and the grey disc this beam is incident on represents the Si wafer, while the grey square represents the translational stage. This is a view from above the setup. The angles of the two beams were not perfectly equivalent, but by "eyeballing" it, the two were very similar (and the exact angle does not matter much, just that the angle is on the other side of the initial angle).

Since the orientation of the stage was not changed, there is nothing to correct for in the beam profiles along the x- and y-directions. The scans for this switched incidence are shown below along with the scan from the initial setup, which I took yesterday.


It is rather clear that these two different scans are almost identical in shape over the x- and y-directions (with the x-direction scan looking almost more similar to the initial incidence scan than the initial vs. switched in the y-direction). The y-direction still gives us a Gaussian and symmetric shape, but with a little skewness maybe in one direction as compared to the initial scan. However, we are most interested in testing the obvious skewness that has been showing up in all of the x-scans as an attempt to see if the incident beam angle was what caused the skewness -- but by looking at the plot of the two x-directional scans, it should be pretty clear that the angle of the incident excitation beam probably does not effect the skewness very much and there is something else that causes this skewness.

One idea (which is pretty simple) is just that there is a misalignment of the parabolic mirrors in the actual microscope design... which is, in theory, why such a profiling technique is useful -- to test the shape of the beam in order to be able to adjust it for the desired shape (probably Gaussian).

Symmetrical Investigation

Today (Monday), I wanted to investigate the skewness of the x-direction lateral scan that I have been discussing for the past few weeks. The easiest way for me to do this was to switch the angle of incidence of the excitation beam, because, if the beam was skewed as a result of the angle of the incident light in the x-direction, then we would expect the exact opposite skewness with the exact opposite angle of incidence. In quiet simple terms, I did exactly this... I switched the angle of incidence so we would in fact see a change in skewness if this was in fact the case.

Before switching the angle and changing the setup too much, I took a scan along the x-direction and a scan along the y-direction for some kind of a reference after switching the setup (though I already had such scans, I wanted to check that nothing had changed much in the design). Plots of this are shown below.


The first plot is that of the x-direction, while the second plot is of the y-direction. We see very much the exact same features that we have been seeing in such x- and y-direction scans -- the x-direction is rather skewed while the y-direction is rather symmetrical and Gaussian looking. This is not much different from what I expected (if they were different, then that would be a problem with the overall technique).

In order to better compare these scans with the scans done in the earlier weeks on the same setup, I simply plotted the x-direction scans all on one plot and all the y-direction scans on another plot. There were three different scans -- one with the first lens I used which did not focus the beam too well, and then two scans with the new lens in place which gave a tighter beam. These plots are shown below.


The first plot is that of the x-direction, while the second is that of the y-direction. The green data correspond to the scans taken with the first lens and at a larger step size (0.25 mm vs. 0.20 mm). This is most likely the reason why the data from this scan looks so much cleaner in a certain sense -- it was less precise. For the x-direction scans, it is clear that there is the same skewness in each scan (though it is a bit harder to see in the "scan 1"). It is especially clear in the difference between "2nd lens (1)" and "2nd lens (2)", as the only real difference is that these scans were taken on different days, which probably explains the difference in amplitude. All of the same sort of features show up in all of theses scans (and especially those of the 2nd lens). Therefore, it might be safe to assume that this method is in fact accurate to a certain extent.

The y-direction scans need much less explaining -- we see a nice, Gaussian shape in almost all of the scans and the main difference becomes the relative amplitude of the scans, though, again, this can (probably) be attributed to the change in laser power over the course of the day.

In fact, I did not take any scans with the new incidence today, but I did get the stage and lens moved to the proper position. I hope to take these scans tomorrow.

Sunday, July 19, 2009

A Few Observations Under N2 Conditions

Today (Friday) and yesterday, I had a chance to look at some of the data that Antoine took last week under conditions in which he filled the microscope chamber with nitrogen gas in order to remove the polar molecules (i.e. water vapor). This was done because we know that THz is absorbed quite readily into polar molecules, of which water vapor is. In almost every spectral plot that I have looked at (many of which are in past posts), we see sharp spikes, or valleys, in which a certain frequency (or band of frequencies) is not very prominent. One suspicion as to what causes these sharp regions of no frequency is absorption of THz into water. Thus, removing the polar molecules may show us some interesting results.

I do not know the conditions too well under which Antoine took the data (as I will need to talk to him about this), but he simply took a few scans at some of the more interesting points of the THz beam. The plot below shows the spectra for the four points that Antoine took scans at. The plot is labelled, and so it should be clear which spectrum corresponds to which position.

There is clearly some very strange things happening here. I do not understand why there are oscillations for each spectra, and I do not understand how a spectrum could have this shape in general. Before I worry about this too much, I would like to talk with Antoine a bit more about his procedure in taking this data and if they usually see things such as this in spectroscopy measurements under N2 conditions.

For the sake of displaying this data, I have also shown a plot of the temporal trace at each of the points that was scanned. I first show the full time-domain traces, and then for the sake of cleanliness, I chop these pulses to try and "zoom in" on the primary pulse. Both plots are shown below.


The colors for each of the specific positions correspond exactly to those in the spectral plot from above. It is clear from these time-domain traces that we still get the reflections that are so obvious in the time-domain traces done without the N2 environment. It does, however, seem as though there may be a significant decrease in the amount of reflections, though these plots do not rightfully show this.

The following plot is that of the time-domain traces at (0,0) for the N2 environment and under the measurements which I made a few weeks ago in which I took four traces and averaged their signal.

This does not seem to tell too much other than there is a lag between the time of the two pulses (due to the speed of light in the given medium) and there is a clear difference in peak amplitude between the two different environmental conditions. There does, however, seem to be a similar amount of reflections/noise after the main pulses for both scans, which might suggest the N2 did not do much to decrease said reflections.

Finally, it is interesting to look at a comparison between the two spectra -- one at (0,0) in N2 and one at (0,0) in the typical environment. Such a plot is shown below, using the same data as the time-domain trace comparison above.

We still see this oscillatory effect in the N2-environment spectrum, while we see nothing of the sort when not using N2. Also, it is clear that there is a much greater percentage of the spectrum which is transmitted through the wafer, as the amplitude of the N2-environment spectrum is greater than that of the other spectrum. Again, I am not very certain why we see such effects using the N2 as opposed to not, but I would like to investigate this a good deal more.

In order to attain a better understanding of these absorptions and anomalies in the spectral plots, I think I first need to be able to truncate the data from the time-domain pulses to hopefully result in a better, smoother-looking spectra. From here I should be able to better determine waist-size dependence on frequency.

Catching Up and Making a Plan

Today (Thursday) was spent in a very similar manner to yesterday. I used my time in the lab to continue catching up with my notebook, blog comments, and notes. I was also able to look at some of the data for the N2 environment that Antoine took last week, however I will use tomorrow's post to write more about what I found. I still am trying to get a finalized plan for what I will be doing the next two weeks here and right now it looks like two main possibilities:

1.) Move everything from the spectroscopy setup to the ellipsometry setup and try to recreate these same results.

2.) Continue trying to understand the specific physical phenomena which occur using my current setup (spectroscopy). This includes mainly (but is not limited to) the skewness in the x-direction of the cross-section of the THz beam and the beam waist size as a function of frequency.

I might feel more comfortable working more on the second choice, though this is yet to be decided.

Thursday, July 16, 2009

Another Day of Catching Up

Having not been in the lab for the past five days, I took today (Wednesday) to catch up on my personal notebook and on the blogger. I did not have a chance to look too much at the blog comments or the data which Antoine took last Friday under N2 gas, and I hope to do so tomorrow. I also have some things that I want to work on changing in the lab which Antoine and I talked about at end of last week. I hope to get this done sometime this week or early next week at the latest.

Wednesday, July 15, 2009

Another Lateral Scan

Today (Thursday) I spent doing some more catching up and also taking another lateral scan of the Si wafer. This scan was done at a fixed position in the x-direction at approxtimately the "bump" that we see in both x-direction lateral scans (see the scans from Monday to see the bump... this was also done using the same, more-focused lens). This was to try and get an idea of the shape of the beam at this one point. Below is a plot of this.

We can see that the shape is indeed rather symmetrical, just with the other scan in the y-direction. There is a fair amount of skewness, as well. The general shape is Gaussian, but it seems to be too "rigid" to be a proper distribution. The whole idea from this scan is that the profile is rather different than what we would expect for a perfect Gaussian distribution.

The problem with doing a series of scans like this over multiple strips of the Si wafer is that we are able to find some rather interesting behavior, but do not have a very good idea what is happening in regions other than those which are scanned. This can be solved in a variety of ways, the easiest being switching out the current translational stage with an automatic one and writing a simple program to profile the entire beam. The problem with this is time and lack of equipment. I have about two weeks remaining, there is not a translational stage laying around that I could use, and there are perhaps more interesting things for me to be looking at.

This being said, I would like to comment on the noise in the signal that I am reading off the lock-in. In case I have not mentioned this before, I take these data manually, and to try and deal with the noise I take and average the highest value and the lowest value over the duration of a few moments. The signal on the lock-in happens to oscillate back and forth, and these maxima and minima are approximately what I average to get the value that I use to plot.

Antoine and I tried to cut-down on this noise later in the day by changing the chopping frequeny, but the best frequency we found was about 283 Hz (frequencies of about 250 Hz and 300 Hz gave a lot of noise due to the surronding environment). In an attempt to see if this averaging technique changes much the final data, I plotted all three sets of data over position (which includes the maximium, average, and minimum). All three series of data seem to correspond well with each other (which simply means that the difference between maximum and miniumum remains relatively consistent, regardless of the position on the wafer -- thus even further suggesting that it is in fact noise). A plot of this is shown below (Note, this is from the same scan that I am describing above, but I see this effect in every scan that I plot maximum, minimum, and average on).


We thought of some ways to reduce this noise, but could not figure anything out right away. I think the easiest thing would be to connect an oscilloscope directly to the lock-in that is able to look at the signal over time and average the signal even more than what the lock-in already is. From this we could hopefully attain a more accurate average value. This idea would not work, however, since we do not have such an oscilloscope around the lab. Also, because of the consistency with the change in signal due to noise, we might as well ignore this for now.

From here I would like to further look into the differences in signal over position and also to continue trying to learn about the waist of the beam as a function of wavelength.